26.11 Audit Note: NA applies when there is no customer requirement to calculate circular mil area.YES/NO/NA

Audit Note: NA applies when there is no customer requirement to calculate circular mil area.

26.12 P- If required, is there a procedure to control multiple wire insertion into a single terminal?YES/NO/NA

26.13 P- If required, is there a procedure for use of fillers in crimp terminals?YES/NO/NA

26.14 P- Unless otherwise specified by the customer, is there a procedure to prevent the crimping of tinned wires?YES/NO/NA

Audit Note: Tinned wire per the IPC-T-50, Tinning – The application of molten solder to a basis metal or surface finish in order to increase its solderability.

26.15 P- Is there a procedure to prevent conductor strands from being cut or modified in any manner to reduce CMA to fit a termination?YES/NO

26.16 C- Is there evidence that procedure for crimping is being followed?YES/NO

26.17 C- Is there evidence that procedure for positioning and placement of wires into terminals to be crimped is being followed?YES/NO

26.18 C- Is the crimping equipment being controlled in accordance with the procedures, including maintenance and calibration?YES/NO

26.19 C- If required, is there evidence that crimping tools other than manufacturer’s approved tooling have been certified prior to use in production?YES/NO/NA

26.20 C- Is documented and approved tooling being used?YES/NO