1. During pd spinup
T31: C0:DM_DevSSUCallback dev 25 Sense Data: Len 12 RespCode 70 senseKey 6 asc 29 ascq 0 <-- Send "Start Stop Unit", received reply "POWER ON, RESET OCCURRED"
T33: C0: Inquiry SU returning Error <-- Send cmd "Inquriy", not successful since it's spinning up
T33: C0:DM_DevSenseRetry: retry with no Sense <-- Retry this cmd, it's successful
T34: C0: Inquiry VPD86 returning Error <-- Send cmd "Inquiry VPD886", received reply "INVALID FIELD IN CDB" since drive doesn't support this page
T34: C0:DM_DevSenseRetry dev 25 Sense Data: Len 12 RespCode 70 senseKey 5 asc 24 ascq 0 <-- Retry this cmd
T34: C0: Inquiry VPD86 returning Error <-- Failed again
T34: C0:DM_DevSenseRetry dev 25 Sense Data: Len 12 RespCode 70 senseKey 5 asc 24 ascq 0 <-- Retry this cmd
T34: C0: Inquiry VPD86 returning Error <-- Failed again
T34: C0:DM_DevSenseRetry dev 25 Sense Data: Len 12 RespCode 70 senseKey 5 asc 24 ascq 0 <-- After 3 times retry, give up and skip to next cmd
2. During enclosure initialization
T34: C0:SES_InitEnclosure: Enclosure 23 : enclIdx: 1 Initialization started
T34: C0:SES_GenericCallback: enclPd=23...RDM_STATUS =1 retries: 0
T34: C0:Cmd Details: 40c64a88 :1c 01 00 00 20 00
T34: C0:SES General Error on EnclPd:23 sts:1 RetryCount:0 msg:40c64a00 txfrAddr:43897fa0 <-- error happens saying "underrun" since Enclosure is initializing, not ready yet, will retry and it's successful.